  Datasheet File OCR Text:
  unisonic technologies co., ltd ut136f/g preliminary triac www.unisonic.com.tw 1 of 3 copyright ? 2011 unisonic technologies co., ltd qw-r401-021.ca triacs ? description passivated triacs in a plastic envelope, suitable for surface mounting, intended for use in applications requiring high bidirectional transient and blocking voltage capability and high thermal cycling performance. typical applications include motor control, industrial and domestic lighting, heating and static switching. ? symbol mt2 mt1 g to-220 1 1 to-252 ? ordering information ordering number pin assignment lead free halogen free package 1 2 3 packing UT136FL-X-TA3-R ut136fp-x-ta3-r to-220 mt1 mt2 g tube ut136gl-x-ta3-r ut136gp-x-ta3-r to-220 mt1 mt2 g tube ut136fl-x-tn3-r ut136fp-x-tn3-r to-252 mt1 mt2 g tape reel ut136gl-x-tn3-r ut136g p-x-tn3-r to-252 mt1 mt2 g tape reel
ut136f/g preliminary triac unisonic technologies co., ltd 2 of 3 www.unisonic.com.tw qw-r401-021.ca ? absolute maximum ratings parameter symbol ratings unit ut136f/g-5 500 (note 2) ut136f/g-6 600 (note 2) repetitive peak off-state voltages ut136f/g-8 v drm 800 v rms on-state current full sine wave, t mb 107c i t(rms) 4 a t = 20ms 25 non-repetitive peak on-state current (full sine wave, t j =25c prior to surge) t = 16.7 ms i tsm 27 a i 2 t for fusing (t =10ms) i 2 t 3.1 a 2 s t2+ g+ 50 t2+ g- 50 t2- g- 50 repetitive rate of rise of on-state current after triggering i tm =6a, i g =0.2a, d ig /dt=0.2a/ s t2- g+ di t /dt 10 a/ s peak gate voltage v gm 5 v peak gate current i gm 2 a peak gate power p gm 5 w average gate power (over any 20ms period) p g(av) 0.5 w junction temperature t j 125 c storage temperature t stg -40 ~ +150 c notes: 1. absolute maximum ratings are those values beyond which the device could be permanently damaged. absolute maximum ratings are stress ratings only and functional device oper ation is not implied. 2. although not recommended, off-state voltages up to 800v may be applied without damage, but the traic may switch to the on-state. the rate of rise of current should not exceed 3a/ s. ? thermal data parameter symbol ratings unit to-220 60 junction to ambient to-252 ja 75 k/w ? static characteristics (t j =25c, unless otherwise specified) max parameter symbol test conditions min typ ut136f ut136g unit t2+g+ 5 25 50 t2+g- 8 25 50 t2-g- 11 25 50 gate trigger current i gt v d =12v, i t =0.1a t2-g+ 30 70 100 ma t2+g+ 7 20 30 t2+g- 16 30 45 t2-g- 5 20 30 latching current i l v d =12v, i gt =0.1a t2-g+ 7 30 45 ma holding current i h v d =12v, i gt =0.1a 5 15 30 ma on-state voltage v t i t =5a 1.4 1.70 v v d =12v, i t =0.1a 0.7 1.5 v gate trigger voltage v gt v d =400v, i t =0.1a, t j =125 c 0.25 0.4 v off-state leakage current i d v d =v drm(max) , t j =125 c 0.1 0.5 ma
ut136f/g preliminary triac unisonic technologies co., ltd 3 of 3 www.unisonic.com.tw qw-r401-021.ca ? dynamic characteristics (t j =25c, unless otherwise specified) min parameter symbol test conditions ut136f ut136g typ max unit critical rate of rise of off-state voltage dv d /dt v dm =67% v drm(max) , t j =125c, exponential waveform, gate open circuit 50 200 250 v/ s critical rate of change of commutating voltage dv com /dt v dm =400v, t j =95c, i t(rms) =4a, di com /dt=1.8a/ms, gate open circuit 10 50 v/ s gate controlled turn-on time t gt i tm =6a, v d =v drm(max) , i g =0.1a, di g /dt=5a/ s 2 s utc assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all utc products described or contained herein. utc products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. the information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice.


▲Up To Search▲   

 
Price & Availability of UT136FL-X-TA3-R

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X